• # EMMI ์ ์™ธ์„  ์—ด์˜์ƒ ๊ฒฐํ•จ ๋ถ„์„ ์žฅ๋น„
  • ์ข…ํ•ฉ๋ฐ˜๋„์ฒด(IDM) / ๋””์Šคํ”Œ๋ ˆ์ด / Junction ๊ทน์†Œ๊ฒฐํ•จ / ๋ถ€ํ’ˆ / PCB ๊ฒฐํ•จ ๋ถ„์„ / ๋ฏธ์„ธ ๊ฒฐํ•จ ๋ถˆ๋Ÿ‰ ์œ„์น˜ ๋ฐ ๊นŠ์ด ์ธก์ •
  • Hot spot(ํ•ซ์Šคํฟ) / ์‡ผํŠธ(Short) & ๋ˆ„์„ค์ „๋ฅ˜(Leakage Current) 
  • # ๋น„์ ‘์ด‰ ๋ฐ•๋ง‰ ๋‘๊ป˜ ์ธก์ •๊ธฐ
  • ๋ฐ˜๋„์ฒด ์žฅ์น˜, ์•ˆ๊ฒฝ, ์Šคํ…ํŠธ, ํƒœ์–‘ ์ „์ง€, ํด๋ฆฌ๋จธ ์ฝ”ํŒ…, ํฌํ† ๋ ˆ์ง€์ŠคํŠธ, ํƒœ์–‘ ์ „์ง€ ํŒจ๋„, LCD, MEMS ๋ฐ ์ฃผ์‚ฌ๊ธฐ ์ œ์กฐ์—…์ฒด
  • 1nm ์—์„œ 2mm ๊นŒ์ง€ ๋‘๊ป˜ ์ธก์ •
  • ํ•™๊ต / ์—ฐ๊ตฌ์‹ค / ์ธ๋ผ์ธ / ๊ณก๋ฉด / ๋Œ€ํ˜• ๋ถ€ํ’ˆ / ๊ฒŒ์ดํŠธํ˜• ๋ฐ•๋ง‰ / ์†Œํ˜• ๋‚œ์‹œ ๋ณด์ • ๋ถ„๊ด‘๊ณ„ ์ธก์ • ๋“ฑ  

EMMI ์ ์™ธ์„  ์—ด์˜์ƒ ๊ฒฐํ•จ ๋ถ„์„ ์žฅ๋น„_์ข…ํ•ฉ๋ฐ˜๋„์ฒด(IDM)/๋””์Šคํ”Œ๋ ˆ์ด/Junction ๊ทน์†Œ๊ฒฐํ•จ/๋ถ€ํ’ˆ/PCB ๊ฒฐํ•จ ๋ถ„์„/์‡ผํŠธ ๋ฐ ๋ˆ„์„ค์ „๋ฅ˜ ๋ฏธ์„ธ ๊ฒฐํ•จ ๋ถˆ๋Ÿ‰ ์œ„์น˜ ๋ฐ ๊นŠ์ด ์ธก์ •

Thermalyze Image Analysis Software(currnet version 7.7.5.0)

Thermalyze


Contact us with information about your application for a Sentris software updates

Thermalyze Prerequisites (version 7.7.0.0 to current)

Core Software PrerequisitesCheck if Required to Update
Matrox Setup
Install only if upgrading from versions below 7.7.0.0
NI Package Manager
Always install most current version available
NI UI
Install only if upgrading from versions below 7.5.0.0
NI Visa Setup
Install only if upgrading from versions below 7.4.0.11
ThermalyzeAlways install
D3XX Driver
Required only for new IS640-17 USB3 cameras

7.7.8.0


Release Date: 09-13-2023

New Features

  • Added support for Matrox Radient camera link board DCF.

Bug Fixes

  • Fixed startup error "milAppError: Allocation error. MsysAlloc The requested system is not (correctly) installed".

  • Measure window now cannot be hidden by Lock-in Thermography window.

  • GenICam functionality added to detect for digitizer error after computer sleep.

  • Delay added to prevent error when transitioning from image capture to camera link board initialization stop.

  • Fixed GenICam error when no ExposureMode selected.

Changes

Version Details

Core Software:



  • Matrox Setup ver 1.2.2

  • NI Package Manager (most recent version)

  • NI UI ver 1.1.0

  • NI Visa Setup ver 19.0

  • D3XX driver ver 1.3.0.4

Dependency Changes

  • Matrox Setup ver 1.2.2 (new version)

Installation Changes

  • Installation password requirement removed.

  • Radient-640x480-16.dcf, Solios-640x480-14.dcf,  Radient-320x240-16.dcf added to Config folder and referenced in Thermalyze.

7.7.7.0


Release Date: 07-24-2023

New Features

  • ReverseX and ReverseY added to Video GenICam Properties window.

  • Main window status bar now displays message when non-radiometric lenses are selected.

  • Connect Online checkbox added to Linear Stage Setup window.

  • Ohm's Law Calculator added to Instrument Control window.

  • Save Startup Settings item added to main Setup menu.

  • Open Control Settings and Save Settings menu items added to Linear Stage Control window file menu.

  • Open Setup Settings menu item added to Linear Stage Setup window file menu.

  • Open Advanced Settings menu item added to Linear Stage Advanced Settings window file menu.

  • Open Settings and Save Settings menu items added to Instrument Control window file menu.

Bug Fixes

  • Video Camera window now supports grayscale formats properly.

  • Video GenICam Properties window now handles properly large values of Packet Delay values.

  • Video GenICam Properties window Acquisition Control Frame Rate now functions properly when Frame Rate Control Enables is not supported by camera.

  • Video GenICam Properties window Packet Size control now increments value properly.

  • Lock-in Phase Image window Auto Scale Each checkbox now functions properly.

  • Lock-in Thermography window now cannot hide Measure window.

  • Fix attempt (not fully tested) IS640-17 image capture bug when camera communication is left on for long periods.

  • Video GenICam code now functions properly when no USB3 or GigE port exists.

Changes

  • Video Settings maximum value for Image Buffers decreased to 20; default value now 10; Command Delay maximum value decreased to 1.

  • Thermalyze now supports up to 10 lenses.

  • Lock-in Overlay Merge Show checkbox automatically unchecked at start of lock-in tests.

  • Instrument Settings NPL Cycles maximum value increased to 10.

Version Details

Core Software:



  • Matrox Setup ver 1.2.0

  • NI Package Manager (most recent version)

  • NI UI ver 1.1.0

  • NI Visa Setup ver 19.0

  • D3XX driver ver 1.3.0.4

Dependency Changes

  • MccDaq.exe version 6.7.4 (supports Windows 11)

Installation Changes

7.7.6.0


Release Date: 06-27-2023

New Features

Bug Fixes

  • Image Sequence Movie Creation now scales properly when  Windows scale factor is not 100%

  • Linear Stage Setup Enable/Disable linear stages now displayed correctly in Linear Stage window

  • Fixed inability to enter color palette values that are outside of slider range

  • Fixed operation of Remove All button in Bad Pixel Replacement window

  • Fixed USB communication conflict with IS320 cameras and the Instrument Control window

  • Fixed Show Image Processing Rate setting always displayed as missing setup at startup

Changes

  • Missing settings window type changed from error to question

Version Details

Core Software:



  • Matrox Setup ver 1.2.0

  • NI Package Manager (most recent version)

  • NI UI ver 1.1.0

  • NI Visa Setup ver 19.0

  • D3XX driver ver 1.3.0.4

Dependency Changes

Installation Changes

  • Program Files\Optotherm\Thermalyze\License folder created during Thermalyze installation

7.7.5.0


Release Date: 05-29-2023

New Features

Bug Fixes

  • Lock-in and Phase windows now correctly auto scale to region

  • Lock-in window color palette scale now drawn correctly when window opens

  • Lock-in Setup window cycle frequencies are now hidden properly for 9Hz camera operation

Changes

Version Details

Core Software:



  • Matrox Setup ver 1.2.0

  • NI Package Manager (most recent version)

  • NI UI ver 1.1.0

  • NI Visa Setup ver 19.0

  • D3XX driver ver 1.3.0.4

Dependency Changes

Installation Changes

7.7.4.0


Release Date: 05-18-2023

New Features

  • Added total of 16 locations to Linear Stage Control window

  • Added Max Setpoint with password protection to Thermal Stage window

Bug Fixes

  • Fixed Breakdown Protection not supported message in Instrument Control window

  • Fixed Overlay where images not 4/3 width/height ratio were stretched or compressed

  • Fixed end point creation bug when Reading value is outside of camera measurement range.

  • Fixed Set Home bug in Linear Stage Control window

  • Fixed Lock-in Thermography window height too short

Changes

  • Serial com ports now saved to Thermalyze.ini as com port name instead of index to prevent issue when operating system reoders com ports

  • Switch positions of Overlay Min and Max controls in main window

  • Default password changed from "1234" to ""

Version Details
Note: All com ports need to be reselected in Thermalyze after installing this version.

Core Software:



  • Matrox Setup ver 1.2.0

  • NI Package Manager (most recent version)

  • NI UI ver 1.1.0

  • NI Visa Setup ver 19.0

  • D3XX driver ver 1.3.0.4

Dependency Changes

Installation Changes


7.7.3.0



Release Date: 05-04-2023

New Features

Bug Fixes

  • Fixed error in pCamSetup.processNewTemps() caused by destination array size of two.

Changes

Version Details

Core Software:



  • Matrox Setup ver 1.2.0

  • NI Package Manager (most recent version)

  • NI UI ver 1.1.0

  • NI Visa Setup ver 19.0

  • D3XX driver ver 1.3.0.4

Dependency Changes

Installation Changes


7.7.2.0



Release Date: 04-20-2023

New Features

  • Stop video capture during Lock-in Tests added to Video Camera Settings window

Bug Fixes

  • Fixed linear stage keyboard control does not function for any stage after a disabled stage

Changes

Version Details

Core Software:



  • Matrox Setup ver 1.2.0

  • NI Package Manager (most recent version)

  • NI UI ver 1.1.0

  • NI Visa Setup ver 19.0

  • D3XX driver ver 1.3.0.4

Dependency Changes

Installation Changes


7.7.1.0



Release Date: 04-10-2023

New Features

  • License File required to run Thermalyze, unlock specific software features and operating modes, and capture thermal images from a specific IS640-17 camera

Bug Fixes

  • Fixed "commands have not finished" interface lockup in Linear Stage Control window

Changes

  •  User inputs set in when Write Settings button clicked in Linear Stage Setup window to ensure operation of safety stop

Version Details

Core Software:



  • Matrox Setup ver 1.2.0

  • NI Package Manager (most recent version)

  • NI UI ver 1.1.0

  • NI Visa Setup ver 19.0

  • D3XX driver ver 1.3.0.4

Dependency Changes

Installation Changes


7.7.0.0



Release Date: 03-31-2023

New Features

  • Keyboard shortcuts window

  • Line Profile X position now displayed in pixel size units, second cursor added with delta displayed, and cursor positions displayed on line profile region

  • Relay support for USB-SSR08

  • Image scale legend on Thermalyze, Lock-in Thermography, and Lock-in Phase Image windows

  • Show center added to Lock-in Phase Image window

  • Palette Auto Scale Each added to Thermalyze window

  • Transfer Thermal Overlay as Overlay added to Lock-in Thermography window

Bug Fixes

  • Fixed User Preferences window Update Image and Update Graphics checkboxes

  • Fixed Thermal Stage window Com Port settings always reverting to 0

  • Fixed region conflict with other displayed graphics such as Show Center crosshairs

  • Fixed Show Center crosshairs deleted when region deleted

  • Regions now visible with overlay merge

Changes

  • When Stop button is pressed on controller, focus is given back to vStageUi after message is sent to vMsgBox

  • If Linear Stage Controller is busy, message box is now not displayed and an alert is sounded

  • Now minimizing main Thermalyze window minimizes all open child windows

  • Region statistic test result data grid background colors optimized for viewing when region is selected and not selected

  • Overlay max and min now defines range of pixel values to merge with overlay

  • Measure window Pixel Size range now 0.1 to 10000

Version Details

Core Software:



  • Matrox Setup ver 1.2.0

  • NI Package Manager (most recent version)

  • NI UI ver 1.1.0

  • NI Visa Setup ver 19.0

  • D3XX driver ver 1.3.0.4

Dependency Changes

  • Matrox Setup ver 1.2.0 (new version)

  • D3XX driver ver 1.3.0.4 (first version)

  • Added reference to FTD3XX.dll

Installation Changes



7.6.0.8



Release Date: 08-22-2022

New Features

  • Video GenICam Properties: ExposureMode property added

Bug Fixes

Changes

Version Details

Core Software:



  • Matrox Setup ver 1.1.0

  • NI Package Manager (most recent version)

  • NI UI ver 1.1.0

  • NI Visa Setup ver 19.0

Dependency Changes

Installation Changes


7.6.0.7



Release Date: 10-31-2022

New Features

  • Enable checkbox added to Instrument Safety window

Bug Fixes

Changes

Version Details

Core Software:



  • Matrox Setup ver 1.1.0

  • NI Package Manager (most recent version)

  • NI UI ver 1.1.0

  • NI Visa Setup ver 19.0

Dependency Changes

Installation Changes


7.6.0.6



Release Date: 10-13-2022

New Features

  • Linear Stage Advanced Settings window Key Control added

Bug Fixes

  • Fixed Lock-in Advanced Save and Export window export Single Phase and Amplitude Overlay check boxes

  • Fixed Strip Chart skipped images when plotting sequence images

  • Fixed Lock-in Phase image size

  • Can now uncheck voltage test boxes in Instrument Control window if communication is lost

  • When saving Lock-in tests, Thermal Model Comparison tests, and sequences leading and trailing spaces are removed from file title because windows folders do not support leading or trailing spaces

  • Added RSYN command to synchronize range with limit to prevent Keithley 2401 problem when current limit is set higher than the present value

Changes

Version Details

Core Software:



  • Matrox Setup ver 1.1.0

  • NI Package Manager (most recent version)

  • NI UI ver 1.1.0

  • NI Visa Setup ver 19.0

Dependency Changes

Installation Changes


7.6.0.5



Release Date: 09-07-2022

New Features

Bug Fixes

Changes

Version Details

Core Software:



  • Matrox Setup ver 1.1.0

  • NI Package Manager (most recent version)

  • NI UI ver 1.1.0

  • NI Visa Setup ver 19.0

Dependency Changes

Installation Changes

  • Added installation of TMC.mdb


7.6.0.4



Release Date: 09-05-2022

New Features

  • Picture overlay can be applied to lock-in images

Bug Fixes

  • Added missing FTD3XX.dll to installation package

  • Fixed display error when Video window is opened but no camera is connected

Changes

Version Details

Core Software:


  • Matrox Setup ver 1.1.0

  • NI Package Manager (most recent version)

  • NI UI ver 1.1.0

  • NI Visa Setup ver 19.0

Dependency Changes

Installation Changes


7.6.0.3



Release Date: 09-04-2022

New Features

  • Picture overlay can be applied to lock-in images

  • Added OffsetX and OffsetY properties in Video Settings window

  • Added User Set features in Video GenICam Properties window

  • Choose to export with/without overlay and Clear All button added to Lock-in Advanced Save and Export window

Bug Fixes

  • All window height and width saved when Thermalyze closes

  • Current and voltage display fixed in Instrument Control window when controlling 2400 series Keithley SMU

  • Measure window stays on top of Lock-in Thermography window

  • Overlay error fixed

  • "Image capture could not be stopped" message prevented

  • Shutterless compensation applied to lock-in cycle images

  • Lock-in images update when test stops

Changes

  • Independent operation of two linear stage controllers in the Linear Stage Control window

  • GenICam operation in Video window made more robust

  • Show Center crosshairs enlarged to width and height of image

Version Details

Core Software:


  • Matrox Setup ver 1.1.0

  • NI Package Manager (most recent version)

  • NI UI ver 1.1.0

  • NI Visa Setup ver 19.0

Dependency Changes

Installation Changes


7.6.0.2



Release Date: 07-25-2022

New Features

  • Added Width and Height properties in Video Settings window

Bug Fixes

  • Uniformity Correction window Save Image saves flipped images correctly

  • Error handling added to property set functions

  • Functionality added to property set functions to properly set numerical edit control Minimum and Maximum properties

  • Fixed Instrument Control and Relay menus and buttons visibility and checked status

Changes

  • Improved GenICam operation in Video window

Version Details

Core Software:


  • Matrox Setup ver 1.1.0

  • NI Package Manager (most recent version)

  • NI UI ver 1.1.0

  • NI Visa Setup ver 19.0

Dependency Changes

Installation Change


7.6.0.1



Release Date: 06-30-2022

New Features

  • Center crosshairs in Lock-in window and main image

  • Lock-in window auto palette scale button

  • Lock-in Hot Spot Location

  • Lock-in Setup Test Duration in hours, minutes and seconds

  • Lock-in Test Time in hours, minutes and seconds

  • Lock-in and Phase image overlay Contrast Enhancement

  • Measurement Settings window

  • Linear Stage Setup window

  • Linear Stage XYZ control with homing, memory locations, indexing and keyboard control

  • Thermalyze version in window title

  • Instrument (Keithley 2470) Breakdown Protection

Bug Fixes

  • New "c:Optotherm\Thermalyze\BPR" folder created at startup

  • Phase image updates when Phase window is opened and lock-in file is opened

  • Lock-in Test Duration stops tests

Changes

  • Video, Picture windows now display size with button instead of drop-down list

  • IV Curve plot axis labels and division no automatically generated

  • Camera Height window renamed to Linear Stage window

  • Video window default parameter changes to Acquisition Mode default = 1, Gain default = 10

  • Second region toolbar button added below main image

Version Details

Core Software:


  • Matrox Setup ver 1.1.0

  • NI Package Manager (most recent version)

  • NI UI ver 1.1.0

  • NI Visa Setup ver 19.0

Dependency Changes

Installation Changes


7.6.0.0



Release Date: 03-30-2022

New Features

  • Shutterless touchup

  • Instrument support for Keithley 2600 source measure units

  • Instrument current sourcing

  • Instrument safety current and voltage

  • Instrument current and voltage range settings

  • Instrument channel settings

  • Instrument support for Sequence and TMC tests

  • Bad pixel replacement

Bug Fixes

  • Bad pixel replacement now performed after lens calibration to fix bad pixel compensation in lens calibration

  • Pre-touchup thermal images now used for lock-in tests to avoid touchup artifacts in lock-in images

  • Fixed 2400 standard series SMU current limit issue

  • Fixed User Preferences window Units selection bug

  • Fixed TMC Test Images message box display opening settings file

  • Fixed region test cell color not changing back to white background

  • Fixed the error displayed as "vProgress: Cannot access a disposed object"

Changes

  • Bad pixel replacement saves all bad pixels in UserBprMask.imb

  • The close camera shutter for lens change feature was removed

  • Instrument output turned off first when Setup Instrument is pressed

Version Details

New shutterless touchup compensation is added in this version which resolves the following issues:

  • Prevents periodic interference with image capture and display

  • Prevents image artifacts and reduced sensitivity in lock-in test images

  • Decreases likelihood of requirement for shutter repair

Note: After installing this version, the camera shutter will open only when image capture begins and will not close when image capture ends.

Core Software:

  • Matrox Setup ver 1.1.0

  • NI Package Manager (most recent version)

  • NI UI ver 1.1.0

  • NI Visa Setup ver 19.0

Dependency Changes

  • Removed references to TIS.Imaging.ICImagingControl34

Installation Changes

  • Removed installation of TIS.Imaging.ICImagingControl34.dll and TIS_UDSHL11_x64.dll

     

Copyright © SEKOA